Skip to main content

Table 1 Comparison of SNs’ detection by ordinary light and infrared light

From: Quantitative assessment of visual estimation of the infrared indocyanine green imaging of lymph nodes retrieved at sentinel node navigation surgery for gastric cancer

 

Ordinary light

Infrared ray light

ICG-positive node

detection

28/36

(78 %)

36/36

The number of

ICG-positive nodes

3.4 ± 3.7*

(0 to 16)+

9.2 ± 5.9*

(2 to 25)+

Lymph node

metastasis sensitivity

1/5

(20 %)

5/5

(100 %)

  1. *mean±SD,+(minimum to maximum)